The box is a rugged weatherproof enclosure that is ideal for both indoor and outdoor applications. Constructed from molded fiberglass reinforced polyester, it is well suited for high temperature or corrosive environments. The mounting flange allows it to be wall mounted as well as on a flat surface. The raised lid features a stainless steel continuous hinge and stainless steel quick release latches with padlock hasps. The raised lid is fully gasketed. The enclosure material is UV stabilized and comes in machine tool gray.
Mounting Plate
The enclosure also features holes for two N-Bulkhead Lightning Protectors or Connectors, a grounding lug and cable conduit connector.
Hot and Cold Environments
To help ensure trouble-free operation of electronic equipment, proper operating temperatures inside an enclosure needs to be maintained. With the built-in Heater and Cooling fan, internal temperatures can be better maintained. This model is ideal in Hot and/or Cold environments.
The HW-N14-1HFS comes with a 120 VAC 200 watt heating element and 120 VAC cooling fan. The fan and heater are controlled by HyperLink’s exclusive solid state temperature controller. The standard unit has a fan turn-on temperature of +93° F (34° C) ±5° and a heat turn-on temperature of +16° F (-9° C ) ±5° The controller features improved temperature setpoint accuracy and can be factory modified for other temperature setpoints. The heater and fan are controlled by two integral high current solid state AC relays. The relays feature Zero Cross Detection for EMI reduction. No extra room for the controller is required since it is mounted underneath the plate. (A minimum order quantity is required for custom fan setpoints and other configurations.)
Lightning Protection
Surge protection is provided as a standard feature on the internal AC outlets. In addition, the unit can accept up to two optional bulkhead-mount N-Type lightning protectors to protect the coaxial cable runs.
- Molded Fiberglass Reinforced Polyester (FRP) industrial Enclosure
- Stainless steel quick release latches with padlock hasps
- NEMA Type 3R, 3RX / IP24 rated
- Fully gasketed raised Vented lid with removable filters & integral mounting flange
- Features aluminum mounting plate with surge protected duplex 120 VAC Outlets & Solid State Thermostat Controlled Heating & Cooling System
Specifications | |
---|---|
Enclosure Material: | Fiberglass Reinforced Polyester |
Enclosure Color: | Machine Tool Gray |
Voltage: | 120 VAC |
Fan Power: | 12 Watts each (24 Watts) |
Mounting Plate Material: | .10 in. (2.5mm) Thick Anodized Aluminum |
Mounting Plate Dimensions: | 12.7 x 10.8 inches (32.2 x 27.4 cm) |
Weight: | 12.5 lbs (5.6 kg) |
Outside Dimensions (max): | 15.5 x 13.5 x 8.7 inches (39.3 x 34.2 x 22 cm) |
Inside Dimensions: | 13.5 x 11.5 x 5.8 inches (34.3 x 29.2 x 14.7 cm) |
Flame Rating: | UL 94-5V |
RoHS Compliant: | Yes |
Cable Feed: | 1/2” Cable Conduit Connector |
Ratings: | NEMA Type 3R; 3RX / IP24 |
Temperature Controller Specification | |
---|---|
Fan Setpoint Temperature: | +32° C (+90° F) |
Heater Setpoint Temperature: | -9° C (+16° F) |
Hysteresis Window: | 5° C (9° F) |